Yieryi Digital Hydrogen Water Tester PH/ORP/Temp/H2 Water ppb ppm Meter with ATC 0.01 Resolution
Yieryi Digital Hydrogen Water Tester PH/ORP/Temp/H2 Water ppb ppm Meter with ATC 0.01 Resolution - 4 in 1 H2 Meter is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
Description
Description
SPECIFICATIONS
Battery: 3*LR44(NOT include)
Brand Name: yieryi
Certification: CE,FCC
Display Type: DIGITAL
Electrode: Replaceable
Function 1: PH Tester
Function 2: ORP Tester
Function 3: H2 Tester
Function 4: Water Temprature Tester
Model Number: ppm Tester YY-400B
Origin: Mainland China
With Backlight Or Not: YES
Yieryi Digital PH/ORP/Temp/H2 Water ppb ppm Meter with ATC 0.01 Resolution High Accuracy Hydrogen Tester for Drinking Water Pool
PH ORP Meter Features:
4-in-1 pH Meter: Yieryi pH tester measures pH, ORP, H2 and temperature simultaneously, providing you with comprehensive information on water quality. Perfect for measuring swimming pools, SPA, Hot Tub Water, aquariums, fish tank water, hydroponics, drinking water, home wine/beer/juice brewing, well water, koi pond water, RO system, aquaculture, etc.. And it can be used for a long time, relatively frequent purchase of test paper or test reagent, can save your money.
Accurate H2 Water Tester: The H2 tester provides two test modes (ppb/ppm), ensuring it meets your needs whether you prefer ppb or ppm mode. Switching between ppb and ppm modes is effortless with a quick press of the MODE/CAL button. No need for complicated color contrasts. Say goodbye to hydrogen test drops and test strips.
3-Point Calibration: The pH meter utilizes a high sensitivity glass probe that measures from 0.00 to 14.00 pH with a resolution of 0.01 pH. Our pH meters utilize a meticulous three-point (4.00, 6.86, and 9.18) calibration to ensure accurate measurements. For your convenience, the pH tester is pre-calibrated and comes with pH calibration powder, so there is no need to purchase additional calibration solutions to use it right out of the box. The pH and ORP testers are available for all your hydrogen water testing needs.
Automatic Temperature Compensation: Our digital pH meter is equipped with automatic temperature compensation, ensuring highly accurate readings despite temperature variations. Unlike conventional pH meters limited to a range of 0°C to 50°C, ours offers a broader operating range from 0°C to 60°C (32°F to 140°F). This extended range effectively minimizes potential errors caused by fluctuating liquid temperatures, thereby enhancing the precision of pH measurements.
Automatic Power-Off Function and Backlit Display: Our pH meter includes an automatic power-off feature, which conserves power by turning it off after 5 minutes of inactivity. Additionally, the pH meter is equipped with a green backlit LCD, ensuring that measurement results are clearly visible in all conditions. Pocket size design to help you measure solution anytime and anywhere.
ppm Tester Specifications:
pH Range: 0.01~14.00pH
Resolution: 0.01pH
Accuracy: ±0.005pH
ORP Range: ±999mV
Resolution: 1mV
Accuracy: ±2mV
H2 Range: 0-2400ppb; 0.001-2.400
Resolution: 2ppb; 2ppm
Accuracy: ±10ppb; ±10ppm
Temperature Range: 0.1-60.0℃ 32.0-140℉
Resolution: 1℃/℉
Accuracy: ±0.5
Operation Environment: 0-60℃(32.0-140℉); RH100%
Waterproof Level: IP67
Battery: 3 * 1.5V(LR44) not include
Screen Size: 33 * 24mm
Size Weight: 183 * 37 * 37mm(7.2 * 1.5 * 1.5in)
Display: LCD digital display
Backlight: Yes
Temperature: Automatic Temperature Compensation 0-60℃
HOLD: Data lock
Automatic Shut-off: 5minutes
Attention: Clean the electrode after using
PH calibration: One point or two points or three points automatically. If the meter can't identify the solution, change the electrode, or contact us.
Only through electrolysis, the hydrogen in the water will be released to form H2, so tap water or drinking water can not be directly measured to PPM or PPB, please electrolyze the water and then measure it, or measure the water in the hydrogen-rich cup.


The hydrogen water ideal pH is 6.5~8.5 and the ORP is -150 ~-850mV.
How to Calibrate the pH ?
1. Before calibration, prepare 3 beakers containing separately 250ml of pH 4.00/pH 6.86/pH 9.18 standard solution.
2. Rinse the electrode with clean distilled water and wipe it dry. Turn on the pH meter and adjust to pH mode.
3. Immerse the electrode into the pH6.86 buffer solution, wait for the value to stabilize, press "CAL" for 5s, and the screen will display "CAL", when pH6.86 flashes 3 times, the calibration of pH6.86 is finished.
4. Repeat the above steps to calibrate pH4.00 or pH9.18.
FQA
Q: What type of battery does the product use? Are batteries shipped?
A: Products generally do not ship batteries, and online logistics cannot transport batteries. The type of battery is 3 * 1.5V (LR44) button battery. Please buy it locally.
Q: What should I do if the received product is damaged, cannot be calibrated, cannot work normally, and the meter cannot recognize the solution?
A: Please protect the product and contact us in time to report product problems
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.